Why You Need a Dk Df Table for Every PCB RF Design
The dielectric constant (Dk) and dissipation factor (Df) of your laminate control trace impedance, signal velocity, and insertion loss at every frequency your board will see. A reliable dk df table for PCB design lets you compare materials side by side, choose the right grade for your frequency band, and feed accurate numbers into your impedance and stackup models before you commit to a fabrication order. Without it, you are guessing—and at 24 GHz or 77 GHz, a Dk error of 0.05 can shift a 50 Ω microstrip by more than 1 mil (0.025 mm) in width.
The searchable table below collects Dk and Df values for more than 200 laminates from Rogers, Isola, Taconic, Panasonic, Arlon, and other major suppliers, all referenced to the vendor’s published 10 GHz test data unless noted otherwise. Use it as a starting point, then refine with the calculators embedded in this article.
Searchable Dk Df Table: PCB Laminate Comparison Database

Our full interactive database lets you sort, filter, and compare laminates by Dk, Df, resin system, thickness, and frequency band. Open it to find the exact grade you need:
→ Dk / Df comparison database with 60+ RF laminates
Below is a representative excerpt from the dk df table covering the most commonly specified PCB laminate families. All Dk values are the “design Dk” (process Dk) at 10 GHz per the manufacturer’s recommendation unless stated otherwise; Df is at the same frequency.
| Laminate | Vendor | Resin System | Dk (10 GHz) | Df (10 GHz) | Typical Use |
|---|---|---|---|---|---|
| RO4350B | Rogers | Hydrocarbon / ceramic | 3.48 | 0.0037 | Base-station filters, small cells |
| RO4003C | Rogers | Hydrocarbon / ceramic | 3.55 | 0.0027 | GPS, WLAN antennas |
| RO3003 | Rogers | PTFE / ceramic | 3.00 | 0.0010 | 77 GHz automotive radar |
| RO3006 | Rogers | PTFE / ceramic | 6.15 | 0.0020 | Size-constrained patch antennas |
| RT/duroid 5880 | Rogers | PTFE / glass microfiber | 2.20 | 0.0009 | Aerospace, phased arrays |
| RT/duroid 6002 | Rogers | PTFE / ceramic | 2.94 | 0.0012 | Satellite feeds, radar |
| I-Tera MT40 | Isola | Hydrocarbon / glass | 3.45 | 0.0031 | High-speed digital, backplanes |
| Astra MT77 | Isola | PTFE / glass | 3.00 | 0.0017 | mmWave 5G, V-band links |
| TLY-5 | Taconic | PTFE / glass | 2.20 | 0.0009 | Low-loss microwave feeds |
| RF-35 | Taconic | PTFE / glass | 3.50 | 0.0018 | Commercial wireless |
| Megtron 6 (R-5775) | Panasonic | PPE / glass | 3.40 | 0.0020 | 112G SerDes, data-center switches |
| Megtron 7 (R-5785) | Panasonic | Modified PPE | 3.30 | 0.0015 | Next-gen 224G PAM4 |
| AD255C | Arlon | PTFE / woven glass | 2.55 | 0.0014 | Phased-array elements |
| AD300D | Arlon | PTFE / ceramic | 3.00 | 0.0030 | Power amplifier substrates |
| FR-4 (standard) | Various | Epoxy / glass | 4.2–4.5 | 0.018–0.025 | Below ~1 GHz digital |
For a deeper dive into Arlon’s RF product line, see our Arlon laminate guide covering AD255C, AD300D, and 25N. If you are new to the concept of dielectric constant itself, start with our explainer on what Dk means in PCB design.
Understanding Dk: What the Numbers in the Dk Df Table Mean for PCB Impedance
Dk determines two things directly: the electrical length of a transmission line and the width needed for a target impedance. A higher Dk shrinks both the wavelength in the substrate and the trace width for a given impedance—useful when board area is tight, but it also narrows manufacturing tolerances.
Dk Tolerance and Drift
No laminate delivers exactly its nominal Dk across every panel, lot, and temperature. Rogers specifies RO4350B with a Dk tolerance of ±0.05 at 10 GHz, while standard FR-4 can swing ±0.3 or more depending on glass-weave style and resin content. Temperature, moisture absorption, and frequency all shift the effective Dk your signal actually sees. Our article on moisture absorption in RF laminates covers how water uptake raises Dk and degrades Df.
Use the estimator below to see how a Dk shift affects your trace impedance. Enter your nominal Dk, the expected drift range, and your target impedance to see the resulting impedance swing.
For example, with a nominal Dk of 3.48 (RO4350B) and a drift of ±0.05, a 50 Ω microstrip shifts roughly ±0.4 Ω—within most system budgets. But the same ±0.05 on a Dk of 2.20 (RT/duroid 5880) produces a proportionally larger percentage change, pushing the swing closer to ±0.7 Ω. This is why low-Dk PTFE designs often need tighter incoming-material verification.
When you are ready to translate Dk into a physical stackup, our RF stackup builder lets you drag and drop cores and prepregs while watching impedance update in real time.
Understanding Df: The Hidden Loss Budget Driver
Df (dissipation factor, also called loss tangent or tan δ) quantifies how much electromagnetic energy the dielectric absorbs and converts to heat per cycle. At low frequencies the difference between Df = 0.020 (FR-4) and Df = 0.0027 (RO4003C) barely matters. At 28 GHz over a 50 mm trace, that gap translates to several dB of additional insertion loss—enough to kill a receiver’s noise figure or force a larger power amplifier.
Estimating Df’s Impact on Insertion Loss
Dielectric loss in dB/unit length scales linearly with frequency and Df. The dielectric-loss component of a microstrip can be approximated as:
α_d ≈ 27.3 × (Dk_eff / Dk) × (Df / √Dk_eff) × (f / c) [dB per unit length]
Rather than work through the algebra by hand, plug your values into the Df Impact Estimator. Enter Dk, Df, frequency, and trace length to get the dielectric insertion-loss contribution.
A typical result: a 25 mm microstrip on Megtron 6 (Dk 3.40, Df 0.0020) at 28 GHz shows roughly 0.9 dB of dielectric loss. Switch to RO3003 (Dk 3.00, Df 0.0010) and that drops to about 0.5 dB—a 0.4 dB saving that compounds across every trace, via transition, and connector in the signal chain. When budgets allow, that difference justifies the higher material cost. When they don’t, the dk df table above helps you find the best Df you can afford in each PCB resin family.
For a broader comparison of how RF laminates differ from standard boards, see RF PCB vs normal PCB: 9 concrete differences.
How to Use the Dk Df Table in Your PCB Design Workflow

- Define your frequency band and loss budget. A 2.4 GHz Wi-Fi front-end can tolerate Df up to ~0.005; a 77 GHz radar needs Df below 0.002.
- Filter the table by Dk range. If your antenna geometry is fixed, you need a specific Dk to hit the right patch dimension or quarter-wave length.
- Check Df at your actual operating frequency. Vendors publish Df at 10 GHz; at 77 GHz, most materials exhibit higher loss. Request the vendor’s frequency-sweep data or consult the Rogers RO4350B product page for extended characterization curves.
- Verify Dk tolerance against your impedance budget. Use the Dk Drift Estimator above to confirm the impedance swing is acceptable.
- Confirm processability. PTFE laminates (Df below 0.0015) often require sodium-etch surface preparation and specialized drilling parameters. Hydrocarbon-ceramic laminates like RO4350B process on standard FR-4 lines.
- Build the stackup and estimate cost. Use our impedance table by material to cross-reference trace widths, then generate a budgetary estimate with the PCB cost estimator.
Key Factors That Shift Dk and Df in Production
Frequency Dependence
Dk generally decreases slightly with frequency for most PTFE and hydrocarbon laminates (a few percent from 1 GHz to 77 GHz), while Df tends to increase. Standard FR-4 shows a much steeper Dk roll-off and Df rise, which is one reason it is unsuitable above a few GHz. Always use the Dk/Df pair at or near your operating frequency, not the 1 MHz values sometimes listed on generic datasheets. A well-maintained dk df table for PCB material selection will note the test frequency alongside every entry.
Temperature
PTFE has a well-known Dk inflection near 19 °C (its crystalline phase transition), where Dk can shift by 0.05–0.10 over a narrow temperature window. Ceramic-filled PTFE grades (RO3003, RO3006) are formulated to flatten this transition. For outdoor or automotive designs, request the vendor’s Dk-vs-temperature plot and design to the worst-case value in your operating range.
Moisture
Water has a Dk of roughly 78 at 1 GHz. Even 0.1 % moisture absorption can raise a laminate’s effective Dk measurably. Low-Df PTFE grades absorb very little moisture (typically 0.02 %), while thermoset hydrocarbon grades sit around 0.05 %. Standard FR-4 can absorb 0.15 % or more. Baking boards before assembly and specifying conformal coating are practical countermeasures.
Glass-Weave Effects
Woven-glass reinforcement creates a non-uniform Dk pattern: the Dk under a glass bundle differs from the Dk between bundles. At frequencies above 10 GHz and for tightly controlled differential pairs, this “fiber weave effect” can cause skew and impedance variation. Spread-glass or flat-glass weave styles (such as Isola’s I-Tera MT40 with spread-glass options) reduce this variation. Alternatively, route traces at an angle to the weave (typically 5°–15° off-axis).
Dk / Df Measurement Methods Behind the Table
The numbers in any dk df table for PCB laminates are only as good as the test method behind them. The three most common approaches, each specified in IPC-TM-650, are:
| Method | IPC-TM-650 Section | Frequency Range | Typical Accuracy |
|---|---|---|---|
| Clamped stripline resonator | 2.5.5.5 | 1–15 GHz | Dk ±0.02, Df ±0.0005 |
| Split-post dielectric resonator (SPDR) | 2.5.5.13 | 1–20 GHz (spot freq.) | Dk ±0.01, Df ±0.0002 |
| Full-sheet resonance (FSR) | 2.5.5.6 | 2–15 GHz | Dk ±0.03 |
Vendors sometimes report a “specification Dk” measured by clamped stripline and a “design Dk” (or “process Dk”) that includes copper-roughness and resin-flow effects. For impedance modeling, always use the design Dk—it better predicts the Dk your signal will experience in the finished board.
Frequently Asked Questions
What is a good Df for RF PCB applications?
For frequencies below 6 GHz, a Df of 0.004 or less (e.g., RO4350B at 0.0037) is generally adequate. Above 10 GHz, target Df below 0.002. For millimeter-wave designs at 60–77 GHz, the best-performing laminates offer Df at or below 0.0012.
Can I use FR-4 Dk/Df values for RF design?
Standard FR-4 has a Dk of 4.2–4.5 and Df of 0.018–0.025 at 1 GHz, both rising unpredictably with frequency. It is usable for non-critical paths below about 1 GHz, but its high Df and loose Dk tolerance make it unsuitable for controlled-impedance RF traces above that.
Why do Dk values differ between datasheets and simulation?
Datasheets report Dk for bare laminate measured in a standardized fixture. Your fabricated board includes copper roughness (which effectively raises Dk by 2–5 %), resin-flow variation, and etch-back effects. Electromagnetic simulators should use the vendor’s “design Dk” or, better, a Dk extracted from a test coupon built on the same stackup.
How does copper roughness interact with Df?
Rough copper increases the effective path length for surface currents, adding conductor loss that can look like elevated Df in S-parameter measurements. When comparing laminates in a dk df table, ensure both PCB substrates are characterized with the same foil type (e.g., rolled-annealed or reverse-treated) to isolate the true dielectric Df.
Where can I find Dk/Df data above 40 GHz?
Most vendor datasheets stop at 10–20 GHz. For higher frequencies, request the vendor’s extended characterization report, or measure your own coupons using a Fabry-Perot open resonator or a waveguide-based transmission/reflection method. Rogers and Isola both publish application notes with data to 77 GHz and beyond for their mmWave product lines.
Ready for a quotation?
Send your requirements for a material, stackup and manufacturing review. Price and schedule are confirmed for your project.